14.2. Settings for maximum depth of detection
<PEGUU> Setting for maximum depth of detection in all metals mode and manual
ground balance:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: of level „0
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of level „0“
<PEAUU> Setting for maximum depth of detection in all metals mode and automatic
ground balance:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „AUTO“
AUTO ZONES switch: position at which the metal detector is balanced to the terrain (position
„3“, „2“ or „1“)
DISCR LEVEL potentiometer: of level „0
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of level „0“
<PDGUU> Setting for maximum depth of detection in discrimination mode and
manual ground balance:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „4“, while at LTC48X v1 of level „6“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of level „5“
<PDAUU> Setting for maximum depth of detection in discrimination mode and
automatic ground balance:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „AUTO“
AUTO ZONES switch: position at which the metal detector is balanced to the terrain (position
„3“, „2“ or „1“)
DISCR LEVEL potentiometer: at LTC48X v2 of level „4“, while at LTC48X v1 of level „6“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of level „5“