14.5. Settings for terrains with high degree of mineralization
<TDAVH> Terrain optimized setting in discrimination mode and automatic ground
balance for no contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „1“ or „3
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „NORM“, while at LTC48X v1 of level „2“
DISCR DEPTH potentiometer: of levels from „9“ to „10“
<TDGVH> Terrain optimized setting in discrimination mode and manual ground
balance for no contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „NORM“, while at LTC48X v1 of level „2“
DISCR DEPTH potentiometer: of levels from „9“ to „10“
<TDACH> Terrain optimized setting in discrimination mode and automatic ground
balance for contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „1“ or „3
DISCR LEVEL potentiometer: at LTC48X v2 of level „6“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „2“, while at LTC48X v1 of level „4“
DISCR DEPTH potentiometer: of level „10“
<TDGCH> Terrain optimized setting in discrimination mode and manual ground
balance for contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „6“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „2“, while at LTC48X v1 of level „4“
DISCR DEPTH potentiometer: of level „10“